Instrumentation Enclosures

Instrument EnclosureLarge Instrument EnclosureInstalled Instrument EnclosureHeated Instrument Enclosure

A wide variety of Instrument Enclosures for a multitude of applications available. Please contact one of our customer service representatives for part numbers, pricing, availability, and applications assistance.

MATERIAL TECHNICAL DATA

IMPACT RESISTANS/MECHANICEL ABUSE

All parts (flat surfaces, corners, etc.) of the enclosures were subject to impact and abuse tests as specified in U.L.

Standard 508.

DIELECTRIC STRENGTH

467 Volts/mill per ASTM D648.

FLAMMABILITY

Self extinguishing (ASTM D635)

HIGH CURRENT ARC IGNITION

Tests terminated after 2000 arcs failed to produce ignition.

HEAT DEFLECTION

Fiberglas enclosures tested ASTM D648. No deflection measured at temperature up to 392°F at which point test

was terminated.

FUME TOXITY

Fumes emitted during burning to destruction are non-toxic in nature, except for some nominal emission of carbon

monoxide, which is common with all organic materials.

TEMPERATURES RESISTANCE

Fiberglass materials are suitable for use in environments of from –58°F to 320°F. Momentary temperatures of 392°

will not be harmful.

WATER ABSORPTION (2 x 2 x 5/32 coupons)

Fiberglass – 45 mg in 4 days

VOLUME RESISTIVITY

Fiberglass lateral tested for volume resistivity to ASTN D257

After 40 hours at 73.4°F, 50% relative humidity – 1 x 1015 ohm cms.

COLOR

Fiberglass is colored a pleasing neutral grey. The color is molded-in and is homogeneous. throughout the material.

Enclousures may be painted with high grade polyurethane or epoxy paints after suitable surface preparation. Specific

details furnished upon request.

STABILITY

DIN53388-7 (best figure by this method is 8). Useful outdoor life for polyester materials exceeds 25 years. Erosion

is less than 3% of thickness over 30 years and does not effect mechanical strength. UV protected throughout the

material.

WORKING QUALITIES

Enclosures may be modified by drilling, sawing, hole punch, etc. The pre-impregnated hot molding process renders

after-treatment of worked areas completely unnecessary.

TROPICAL DUTY

Suitable for use in tropical service. Tropical environment tests, to IEC68-2, were performed without damage to

enclosures, also resisting mold, fungus growth, etc.

VERMIN; TERMITES; ETC:

Enclosures will resist attack by rodents, vermin, termites, etc.

Instrument protection systems ensure safe operation of process control instruments, on-line analyzers, mobile phone and radar equipment, signaling plants, transmitters and many other installations worldwide.

Neglect or failures in instrument protection can seriously affect plant safety and the operation of the complete system. Even operating and maintenance costs can be reduced considerably by providing adequate instrument protection.